Model | Unit Type | Application | Voltage | Horse Power | Refrigerant |
---|---|---|---|---|---|
AWS4515YGENA | Indoor | HBP, MBP | 230V 1PH 50Hz | 3 HP | R-134a |
AWS4518YXCNB | Indoor | HBP, MBP | 220-240V 1PH 50Hz | 3 HP | R-134a |
CDS2438ZKS | Outdoor | LBP | 230V 1PH 50Hz | 1/8 HP | R-404A |
CDS2446ZKS | Outdoor | LBP | 230V 1PH 50Hz | 1/8 HP | R-404A |
CDS2470ZGE | Outdoor | LBP | 230V 1PH 50Hz | 1/8 HP | R-404A |
CDS4466YKS | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1/8 HP | R-134a |
CDS4475YKSXR | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1/8 HP | R-134a |
CDS4489YKS | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1/8 HP | R-134a |
CDS4540CGF | Outdoor | AC, HBP | 400V 3PH 50Hz | 2 HP | R-407C |
CDS4542EXG | Outdoor | HBP, MBP | 380-420V 3PH 50Hz | 2 HP | R-22 |
CDS4542WXG | Outdoor | AC, HBP | 400V 3PH 50Hz | 2 HP | R-22, R-407C |
CDS5515WGE | Outdoor | HBP, MBP | 230V 1PH 50Hz | 2 HP | R-22, R-407C |
CDS5522EGE | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1 1/2 HP | R-22 |
CDS5522WGE | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1 1/2 HP | R-22, R-407C |
CDS5522WGE-GC | Outdoor | HBP, MBP | 230V 1PH 50Hz | 1 1/2 HP | R-22, R-407C |
CDS5522WGF | Outdoor | HBP, MBP | 400V 3PH 50Hz | 1 1/2 HP | R-22, R-407C |
AWS4515YGENA
Unit Type:Indoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:3 HP
Refrigerant:R-134a
AWS4518YXCNB
Unit Type:Indoor
Application:HBP, MBP
Voltage:220-240V 1PH 50Hz
Horse Power:3 HP
Refrigerant:R-134a
CDS4466YKS
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1/8 HP
Refrigerant:R-134a
CDS4475YKSXR
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1/8 HP
Refrigerant:R-134a
CDS4489YKS
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1/8 HP
Refrigerant:R-134a
CDS4540CGF
Unit Type:Outdoor
Application:AC, HBP
Voltage:400V 3PH 50Hz
Horse Power:2 HP
Refrigerant:R-407C
CDS4542EXG
Unit Type:Outdoor
Application:HBP, MBP
Voltage:380-420V 3PH 50Hz
Horse Power:2 HP
Refrigerant:R-22
CDS4542WXG
Unit Type:Outdoor
Application:AC, HBP
Voltage:400V 3PH 50Hz
Horse Power:2 HP
Refrigerant:R-22, R-407C
CDS5515WGE
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:2 HP
Refrigerant:R-22, R-407C
CDS5522EGE
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1 1/2 HP
Refrigerant:R-22
CDS5522WGE
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1 1/2 HP
Refrigerant:R-22, R-407C
CDS5522WGE-GC
Unit Type:Outdoor
Application:HBP, MBP
Voltage:230V 1PH 50Hz
Horse Power:1 1/2 HP
Refrigerant:R-22, R-407C
CDS5522WGF
Unit Type:Outdoor
Application:HBP, MBP
Voltage:400V 3PH 50Hz
Horse Power:1 1/2 HP
Refrigerant:R-22, R-407C